Smartphone-generated physiological data (SGPD), such as remote photoplethysmography (rPPG) captured through a smartphone camera, offers a low-burden channel for population-scale depression screening, but real-world SGPD is noisy in ways prior work has not systematically addressed. We propose a three-layer noise taxonomy, human, technical, and contextual, and a three-module framework that operationalizes it: Confident Learning for label noise correction, a Biodynamics-Guided CNN embedding a first-order autonomic regulation constraint, and deep ensemble uncertainty quantification. Using SGPD from 67,801 participants in a nationwide occupational health examination, our model achieves balanced accuracy of 0.758, recall of 0.835, and AUROC of 0.822, rising to 0.909 balanced accuracy in a subgroup independently confirmed through suicidal-ideation disclosure. Ablations show that the biodynamics-guided constraint’s contribution to recall is conditional on prior label correction, consistent with the framework’s sequential design. Uncertainty analysis explains up to 35% of prediction-reliability variance, providing actionable guidance for equitable, noise-robust SGPD-based mental health screening.

Comments

19_Healthcare_and_wellbeing

Share

COinS
 
Dec 14th, 12:00 AM

Noise-Robust Depression Screening using Smartphone-Generated Physiological Data: A Three-Module Framework

Smartphone-generated physiological data (SGPD), such as remote photoplethysmography (rPPG) captured through a smartphone camera, offers a low-burden channel for population-scale depression screening, but real-world SGPD is noisy in ways prior work has not systematically addressed. We propose a three-layer noise taxonomy, human, technical, and contextual, and a three-module framework that operationalizes it: Confident Learning for label noise correction, a Biodynamics-Guided CNN embedding a first-order autonomic regulation constraint, and deep ensemble uncertainty quantification. Using SGPD from 67,801 participants in a nationwide occupational health examination, our model achieves balanced accuracy of 0.758, recall of 0.835, and AUROC of 0.822, rising to 0.909 balanced accuracy in a subgroup independently confirmed through suicidal-ideation disclosure. Ablations show that the biodynamics-guided constraint’s contribution to recall is conditional on prior label correction, consistent with the framework’s sequential design. Uncertainty analysis explains up to 35% of prediction-reliability variance, providing actionable guidance for equitable, noise-robust SGPD-based mental health screening.

When commenting on articles, please be friendly, welcoming, respectful and abide by the AIS eLibrary Discussion Thread Code of Conduct posted here.