Presenter Information

Paper Number

ICIS2026-1133

Paper Type

Short

Abstract

Specialized movement-analysis systems provide rehabilitation evidence but impose equipment, setup, and expertise demands that constrain routine access. This design science study develops a working dual-view Timed Up and Go (TUG) artifact that transforms ordinary front- and side-view video into phase-aware candidate measures and a therapist-facing report. Three frontline rehabilitation practitioners informed requirements, demonstrations, and output review; a rehabilitation physician participated in the broader project. A documented review raised 13 questions about phase scope, calculation, units, video-value disagreement, and acquisition conditions. We also report two therapist-performed same-episode comparisons between prototype and hospital reference outputs. Agreement varied by parameter: sit-to-stand times differed by 0.1 seconds, whereas turn timing, step counts, walking speed, step width, and some step-length estimates diverged substantially. The paper contributes an implemented capture-to-report artifact and nascent design knowledge: lower-infrastructure sensing becomes useful only when task decomposition, measurement qualification, information representation, and professional review are designed end to end.

Comments

19_Healthcare_and_wellbeing

Share

COinS
 
Dec 14th, 12:00 AM

From Ordinary Cameras to Rehabilitation Information: A Dual-View TUG Artifact

Specialized movement-analysis systems provide rehabilitation evidence but impose equipment, setup, and expertise demands that constrain routine access. This design science study develops a working dual-view Timed Up and Go (TUG) artifact that transforms ordinary front- and side-view video into phase-aware candidate measures and a therapist-facing report. Three frontline rehabilitation practitioners informed requirements, demonstrations, and output review; a rehabilitation physician participated in the broader project. A documented review raised 13 questions about phase scope, calculation, units, video-value disagreement, and acquisition conditions. We also report two therapist-performed same-episode comparisons between prototype and hospital reference outputs. Agreement varied by parameter: sit-to-stand times differed by 0.1 seconds, whereas turn timing, step counts, walking speed, step width, and some step-length estimates diverged substantially. The paper contributes an implemented capture-to-report artifact and nascent design knowledge: lower-infrastructure sensing becomes useful only when task decomposition, measurement qualification, information representation, and professional review are designed end to end.

When commenting on articles, please be friendly, welcoming, respectful and abide by the AIS eLibrary Discussion Thread Code of Conduct posted here.