Paper Number
ICIS2026-1133
Paper Type
Short
Abstract
Specialized movement-analysis systems provide rehabilitation evidence but impose equipment, setup, and expertise demands that constrain routine access. This design science study develops a working dual-view Timed Up and Go (TUG) artifact that transforms ordinary front- and side-view video into phase-aware candidate measures and a therapist-facing report. Three frontline rehabilitation practitioners informed requirements, demonstrations, and output review; a rehabilitation physician participated in the broader project. A documented review raised 13 questions about phase scope, calculation, units, video-value disagreement, and acquisition conditions. We also report two therapist-performed same-episode comparisons between prototype and hospital reference outputs. Agreement varied by parameter: sit-to-stand times differed by 0.1 seconds, whereas turn timing, step counts, walking speed, step width, and some step-length estimates diverged substantially. The paper contributes an implemented capture-to-report artifact and nascent design knowledge: lower-infrastructure sensing becomes useful only when task decomposition, measurement qualification, information representation, and professional review are designed end to end.
Recommended Citation
Chen, Juan, "From Ordinary Cameras to Rehabilitation Information: A Dual-View TUG Artifact" (2026). ICIS 2026 Proceedings. 1.
https://aisel.aisnet.org/icis2026/health/health/1
From Ordinary Cameras to Rehabilitation Information: A Dual-View TUG Artifact
Specialized movement-analysis systems provide rehabilitation evidence but impose equipment, setup, and expertise demands that constrain routine access. This design science study develops a working dual-view Timed Up and Go (TUG) artifact that transforms ordinary front- and side-view video into phase-aware candidate measures and a therapist-facing report. Three frontline rehabilitation practitioners informed requirements, demonstrations, and output review; a rehabilitation physician participated in the broader project. A documented review raised 13 questions about phase scope, calculation, units, video-value disagreement, and acquisition conditions. We also report two therapist-performed same-episode comparisons between prototype and hospital reference outputs. Agreement varied by parameter: sit-to-stand times differed by 0.1 seconds, whereas turn timing, step counts, walking speed, step width, and some step-length estimates diverged substantially. The paper contributes an implemented capture-to-report artifact and nascent design knowledge: lower-infrastructure sensing becomes useful only when task decomposition, measurement qualification, information representation, and professional review are designed end to end.
When commenting on articles, please be friendly, welcoming, respectful and abide by the AIS eLibrary Discussion Thread Code of Conduct posted here.
Comments
19_Healthcare_and_wellbeing